• Home
  • About Us
  • Services
  • Fire Extinguishers
    • ABC Type Fire Extinguishers
    • CO2 Type Fire Extinguishers
    • DCP Type Fire Extinguishers
    • W/CO2 Type Fire Extinguishers
    • M/Foam Type Fire Extinguishers
    • Modular Type Fire Extinguishers
  • Projects
    • Fire Hydrant System
    • Fire Sprinkler System
    • Fire Alarm System
    • CCTV Surveillance System
    • Personal Protective Equipment
  • Products
    • Fire Fighting Equipment
    • Fire Alarm Devices
    • Personal Protective Equipment
  • Enquiry Form
  • Contact Us
  • Facebook  
  • Twitter  
  • Google+  

Water Based Sprinkler

Spray Nozzle ( Medium Velocity Nozzle )

Product
Code No.
Description Threaded
Inlet
Connection
‘K’ Factor Spray
Angle In
Degree
Material
Of Construction
Finish
SSE-SN-M-01 ½” Size BSP
BSPT
NPT
24, 28, 31,
36, 41, 45,
51, 57, 61,
66, 71, 76,
81, 86, 91
60,75,80,
90,100,110,
120,140,180
Forged Brass Natural
Crome Plated
SSE-SN-M-02 ¾” Size

High Velocity Nozzle

Product
Code No.
Description Threaded
Inlet
Connection
‘K’ Factor Spray
Angle In
Degree
Material
Of Construction
Finish
SSE-SN-H-01 ¾” Size BSP
BSPT
NPT
18
25
32
47
75
80
85
90
Brass
S.S 304
Natural
Crome Plated
SSE-SN-H-02 ¾” Size

Pendent Type

  • UL Listed
  • Made out of bronze
  • Maximum Working pressure 175 PSI
Product Code No. Description Inlet
Connection
Finish
SSE-AS-P-57 Rated Temp 57°

½” NPT

½” PT

Natural

Cromeplated

SSE-AS-P-68

Rated Temp 68° UL Listed

SSE-AS-P-79

Rated Temp 79° UL Listed

SSE-AS-P-93 Rated Temp 93°
SSE-AS-P-141 Rated Temp 141°

Upright Type

  • UL Listed
  • Made out of bronze
  • Maximum Working pressure 175 PSI
Product Code No. Description Inlet
Connection
Finish
SSE-AS-UP-57 Rated Temp 57°

1/2” NPT

1/2” PT

Natural

Cromeplated

SSE-AS-UP-68 Rated Temp 68°
UL Listed
SSE-AS-UP-79 Rated Temp 79°
UL Listed
SSE-AS-UP-93 Rated Temp 93°
SSE-AS-UP-141 Rated Temp 141°

Side Wall Mounted Type

  • Made out of bronze
  • Maximum Working pressure 175 PSI
Product Code No. Description Inlet
Connection
Finish
SSE-AS-SW-57 Rated Temp 57°

½” NPT

½” PT

Natural

Cromeplated

SSE-AS-SW-68 Rated Temp 68°
UL Listed
SSE-AS-SW-79 Rated Temp 79° UL Listed
SSE-AS-SW-93 Rated Temp 93°
SSE-AS-SW-141 Rated Temp 141°

Concealed Type

It is two-piece type adjustable type with pendent sprinkler to provide low profile decorativesprinkler. Two-piece design allows the installation and testing of sprinkler prior to installation of the ceiling. Outer Cap can remove and re-install allowing access above removable ceiling panels for servicing building equipment without shutting down the sprinkler system and removing the removing the sprinkler the slip-on feature allows for minor adjustments due to pipe or ceiling pitch.

  • Discharge Rate : 22 GPM
  • Maximum Working pressure 150 PSI/li>
  • Nominal Temp. : 68°/li>
  • Radius of effective coverage : 2.3 meter/li>
  • Hole dia Require In ceiling : 60 to 70 mm/li>
  • Fusible Metal : Tin Alloy about 60°I
Product Code No. Description
SSE-AS-C-68 As Above

Deluge Valve

  • UL listed
  • Made out of Cast Iron
  • Rated pressure 175 PSI
  • Test Pressure 350 PSI
Product Code No. Description
SSE-DV-01 2” Threaded Connection Horizontal Pattern
SSE-DV-02 2” Flanged Connections Horizontal Pattern

Alarm Valve

  • UL listed
  • Made from Cast Iron
  • Rated pressure 175 PSI
  • Test Pressure 350 PSI
Product Code No. Description
SSE-AV-01 4” Flanged Connection Vertical Installed
SSE-AV-02 6” Flanged Connection Vertical Installed

Sprinkler Valve Hose

As widely used for regular building and always having water in the inlet and outlet six of the alarm valve, wet pipe sprinkler system enables prompt fire suppression in case of fire.

  • Home
  • About Us
  • Services
  • Fire Fighting Equipment
  • Fire Alarm Devices
  • PPE
  • Enquiry
  • Contact

Copyright © 2015. Universal Fire & Safety Services. All Rights Reserved.
Developed and Managed by SME Business Services Ltd.